EN / 中文

thermal actuator, thermostatic element, thermostatic valve, thermostatic radiator, thermoelectric actuator

  • Home
  • Company
    • About Us
    • Product Introduction
    • Application & Solution
  • Innovation
  • Product
    • Customized Thermal Actuator/Valve
      • Thermal Actuator for Marine Solution
      • TV/HAT Temperature Control Valve
      • Thermoactuator
    • T&P Relief Valve
      • Standard T&P Relief Valve
      • T&P Relief Valve for Air Compressor
      • T&P Relief Valve for Steam Boiler
    • Probe for T&P valve
    • Thermoelectric Actuator
      • 500 series thermoelectric actuator
      • 501 series thermoelectric actuator
      • 504 series thermoelectric actuator
    • Thermostatic Control Valve
      • 300 series
      • 301 series
    • Thermostatic Mixing Valve
      • 0829
      • 5464
    • Freeze Protection Valve
    • VAV Diffuser Thermostatic Element
    • Automobile Thermal Control
      • Auto Engine Thermal Control
      • Diesel Filter Element
  • News
  • Contact
  • Chinese
  • Home
  • News
  • thermal actuator News
  • Talking about the Control Application of Unified Power Flow Controller UPFC in Power Grid
 

Talking about the Control Application of Unified Power Flow Controller UPFC in Power Grid

by admin / 2019/09/06 / Published in thermal actuator News

In recent years, the regulation power of reactive power compensation in power grid has become more and more demanding, especially in the low period, the demand for inductive reactive power is larger. Through the comparison of power flow simulation calculation, this paper demonstrates that adding UPFC in intelligent substation can improve the system voltage stability margin and effectively improve the transmission capacity of the channel.

Talking about the Control Application of Unified Power Flow Controller UPFC in Power Grid_no.192

  Unified Power Flow Controller (UPFC) can adjust three important parameters affecting power flow in real time: voltage, phase angle and impedance to compensate reactive power and optimize power system. By comparing the data of simulation calculation of N-1 fault power flow with UPFC and without UPFC, thermostatic element this paper discusses the control application of UPFC in power grid.

Talking about the Control Application of Unified Power Flow Controller UPFC in Power Grid_no.57

  UPFC consists of two parts: parallel converter and series converter. Converter 1 is connected to the system through parallel transformer and converter 2 is connected to the system through series transformer.
This “back-to-back” connection method makes the active power between the two converters flow bidirectionally, and can emit or absorb the reactive power of the AC system.
It is this structure that determines the functions of parallel and series compensation. PI control divides UPFC into internal control and external control in function, in which the internal control part is responsible for issuing trigger signals of inverters, and the external control part is responsible for issuing signals of series injection voltage and parallel extraction current.
The idea of UPFC control in this paper is divided into two parts: system level control and converter control. Taking a district power grid as an example, there are three routes between BUS1 and BUS2.

Talking about the Control Application of Unified Power Flow Controller UPFC in Power Grid_no.133

  Because the length of line A is about 11 km, while the length of the other two lines is about 7 km, the impedance of the three lines is different and the power flow distribution of the lines is uneven. From the following power flow chart, it can be seen that when line A reaches the quota of 310MW after the fault of line 3, line B only conveys 262MW of power flow (considering the dynamic capacity increase of overhead lines, the transmission capacity reaches the quota of 310MW of cable segment). Therefore, the actual transmission capacity of line N-1 of this channel is about 570MW.
From the above power flow, it can be seen that the impedance distribution of BUS1-BUS2 three loops runs side by side and is uneven.
Therefore, UPFC installed on line A is considered to compensate the impedance, so as to realize the reasonable distribution of power flow and improve the transmission capacity of the tie-in channel. Considering that the maximum transmission capacity of 310MW of each line on the channel can be fully utilized, the load of BUS1-BUS2 channel is set to about 620MW for power flow calculation. From the calculation results, it can be seen that after UPFC is installed in the power system, the N-1 fault transmission capacity of BUS1-BUS2 lines can be increased from 570 MW after dynamic capacitation to 620 MW. By comparing the fault power flow calculation of N-1 transmission line with UPFC and without UPFC, it is found that the dynamic capacity of N-1 transmission line can be greatly improved after UPFC is installed in power system.
In addition, UPFC provides dynamic reactive power support to improve the system voltage stability margin and alleviate the problem of inductive static reactive power shortage.
This paper proves that UPFC has a wide range of practicability in engineering through a specific case study.

ARCHIVES

  • October 2019
  • September 2019
  • August 2019
  • April 2019
  • August 2018
  • July 2018
  • June 2018
  • May 2018
  • April 2018
  • January 2018
  • October 2017

CATEGORIES

  • News
  • Technology
  • thermal actuator News

COMPANY

  • About Us
  • Product Introduction
  • Innovation
  • Application & Solution
  • Terms of Use

PRODUCT

  • Customized Thermal Actuator/Valve
    • Thermal Actuator for Marine Solution
    • TV/HAT Temperature Control Valve
    • Thermoactuator
  • T&P Relief Valve
    • Standard T&P Relief Valve
    • T&P Relief Valve for Air Compressor
    • T&P Relief Valve for Steam Boiler
  • Probe for T&P valve
  • Thermoelectric Actuator
  • Thermostatic Control Valve
    • 300 series
    • 301 series
  • Thermostatic Mixing Valve
  • Freeze Protection Valve
  • VAV Diffuser Thermostatic Element
  • Automobile Thermal Control
    • Auto Engine Thermal Control
    • Diesel Filter Element

CONTACT

Tel.: (+86) 574 8805 9937

Mob./Whatsapp: (+86) 180 6927 2889

Email: sales@wisdom-thermostats.com

Zhejiang WISDOM Thermostats Technologies Co., Ltd.

Add.: No. 615 Xiaogao West Road, Ningbo 315000, China

© 2015 Zhejiang Wisdom Thermostats Technologies Co., Ltd. all rights reserved.

TOP