EN / 中文

thermal actuator, thermostatic element, thermostatic valve, thermostatic radiator, thermoelectric actuator

  • Home
  • Company
    • About Us
    • Product Introduction
    • Application & Solution
  • Innovation
  • Product
    • Customized Thermal Actuator/Valve
      • Thermal Actuator for Marine Solution
      • TV/HAT Temperature Control Valve
      • Thermoactuator
    • T&P Relief Valve
      • Standard T&P Relief Valve
      • T&P Relief Valve for Air Compressor
      • T&P Relief Valve for Steam Boiler
    • Probe for T&P valve
    • Thermoelectric Actuator
      • 500 series thermoelectric actuator
      • 501 series thermoelectric actuator
      • 504 series thermoelectric actuator
    • Thermostatic Control Valve
      • 300 series
      • 301 series
    • Thermostatic Mixing Valve
      • 0829
      • 5464
    • Freeze Protection Valve
    • VAV Diffuser Thermostatic Element
    • Automobile Thermal Control
      • Auto Engine Thermal Control
      • Diesel Filter Element
  • News
  • Contact
  • Chinese
  • Home
  • News
  • thermal actuator News
  • Comparison of Zero-pole Configuration and PID Controller Design in Computer Control System
 

Comparison of Zero-pole Configuration and PID Controller Design in Computer Control System

by admin / 2019/09/03 / Published in thermal actuator News

In order to solve the connection and difference between zero-pole placement design controller and digital PID controller of linear system in the course of teaching computer control system, a simulation teaching example of MATLAB/SIMULINK is designed to understand and compare the controller design method of computer control system based on continuous domain. The zero-pole placement design controller and digital PID controller of computer control system belong to the design method of digital controller based on continuum theory [1] [2]. Different from the direct design method of the discrete domain of digital controller, it is easy to understand, and it is still used by many scientists and technicians, especially the design method of digital PID controller. In this paper, an example is designed by using MATLAB and SIMULINK simulation [3].
Zero-pole placement controller and PID controller are designed for the same linear system controlled object.

Comparison of Zero-pole Configuration and PID Controller Design in Computer Control System_no.216

  

Comparison of Zero-pole Configuration and PID Controller Design in Computer Control System_no.43

  Detailed steps of controller design are given, and the two design methods and system performance are compared. The method of continuous system theory is required to design digital controllers so that the closed-loop system satisfies the steady-state error e(_) = 0, the step response overshoot_%<10%, the regulation time T < 1.2s ( 2% error band), and the sampling period T=0.
1s. It is a generalized continuous controlled object. The SISOTOOL toolbox in MATLAB is used to assign zero and pole points to the generalized controlled object to meet the performance index of the desired closed-loop system. The designed computer control system is verified and simulated in SIMULINK.
As shown in Figure 4, thermostatic element it can be seen that the designed controller fully meets the expected performance indicators.

Comparison of Zero-pole Configuration and PID Controller Design in Computer Control System_no.90

  The simulation program is written by Simulink as shown in Fig. 5, and a set of reasonable PID parameters (which can be adjusted by critical scale method, etc.) are obtained to meet the expected performance requirements.

Comparison of Zero-pole Configuration and PID Controller Design in Computer Control System_no.53

  The two design methods of digital controllers based on continuous domain discussed above have their own advantages and disadvantages. The pole placement design method is easy to understand the essence of digital controller design, but the process is more cumbersome. The digital PID design method is simple and easy to apply in engineering.

ARCHIVES

  • October 2019
  • September 2019
  • August 2019
  • April 2019
  • August 2018
  • July 2018
  • June 2018
  • May 2018
  • April 2018
  • January 2018
  • October 2017

CATEGORIES

  • News
  • Technology
  • thermal actuator News

COMPANY

  • About Us
  • Product Introduction
  • Innovation
  • Application & Solution
  • Terms of Use

PRODUCT

  • Customized Thermal Actuator/Valve
    • Thermal Actuator for Marine Solution
    • TV/HAT Temperature Control Valve
    • Thermoactuator
  • T&P Relief Valve
    • Standard T&P Relief Valve
    • T&P Relief Valve for Air Compressor
    • T&P Relief Valve for Steam Boiler
  • Probe for T&P valve
  • Thermoelectric Actuator
  • Thermostatic Control Valve
    • 300 series
    • 301 series
  • Thermostatic Mixing Valve
  • Freeze Protection Valve
  • VAV Diffuser Thermostatic Element
  • Automobile Thermal Control
    • Auto Engine Thermal Control
    • Diesel Filter Element

CONTACT

Tel.: (+86) 574 8805 9937

Mob./Whatsapp: (+86) 180 6927 2889

Email: sales@wisdom-thermostats.com

Zhejiang WISDOM Thermostats Technologies Co., Ltd.

Add.: No. 615 Xiaogao West Road, Ningbo 315000, China

© 2015 Zhejiang Wisdom Thermostats Technologies Co., Ltd. all rights reserved.

TOP